OCPP messages¶
SME OCPPSim simulates OCPP 1.6J charge points and OCPP 2.0.1 charging stations; ocpp_version selects the
version per charger or for all of them (see Configuration). Any action received from the
CSMS that is not supported is answered with CALLERROR NotImplemented and recorded in the frame log.
OCPP 1.6J¶
Subprotocol ocpp1.6.
Charge point to CSMS¶
| Action | Notes |
|---|---|
| BootNotification | Accepted / Pending / Rejected. On Pending / Rejected the charger retries after interval (or boot_retry_s when the interval is 0) and in the meantime only answers CSMS requests |
| Heartbeat | currentTime is used to record the clock offset |
| StatusNotification | Connector 0 and every connector; errorCode, info, vendorErrorCode |
| Authorize | Depends on auth_mode (see Configuration) |
| StartTransaction | Receives the transactionId; a non-Accepted idTagInfo stops the transaction |
| StopTransaction | reason, transactionData: the StopTxnSampledData measurands every MeterValueSampleInterval from the start of the transaction (Sample.Periodic) and at the end (Transaction.End), the StopTxnAlignedData measurands at every ClockAlignedDataInterval boundary (Sample.Clock); none when both keys are empty. A measurand the meter does not report (other than Energy.Active.Import.Register, Power.Active.Import, Current.Import, Voltage, SoC) or a list longer than its *MaxLength key is Rejected by ChangeConfiguration |
| MeterValues | Sampled every MeterValueSampleInterval during a transaction; measurands from MeterValuesSampledData; with location / context. Clock-aligned MeterValues messages (ClockAlignedDataInterval / MeterValuesAlignedData) are not sent yet (StopTxnAlignedData readings in transactionData are) |
| DataTransfer | Sent manually from the UI or the HTTP API |
| FirmwareStatusNotification | Downloading → Downloaded → Installing → (reboot, BootNotification) → Installed; DownloadFailed / InstallationFailed by failure injection |
| DiagnosticsStatusNotification | Uploading → Uploaded / UploadFailed |
| SecurityEventNotification | Security Whitepaper; the same events as 2.0.1, with the 1.6 names InvalidCentralSystemCertificate / FailedToAuthenticateAtCentralSystem / InvalidChargePointCertificate (critical ones queued while offline) |
| SignCertificate | Security Whitepaper; after ExtendedTriggerMessage SignChargePointCertificate: a new key and CSR (CN = serial or the charger id, O = CpoName, default vendor) |
Transaction-related messages (StartTransaction, StopTransaction, periodic MeterValues) and state-change
StatusNotifications go through one ordered queue. A message whose answer was lost in a disconnect is resent
after the next accepted boot, so the CSMS may receive it twice (1.6 has no idempotency key). Failed transaction
messages are retried TransactionMessageAttempts times at TransactionMessageRetryInterval.
CSMS to charge point¶
| Action | Notes |
|---|---|
| RemoteStartTransaction | May carry a chargingProfile (TxProfile without transactionId). Rejected before the boot is accepted |
| RemoteStopTransaction | |
| GetConfiguration | An empty key list returns all keys; unknown keys go to unknownKey. Answered even before the boot is accepted. The write-only AuthorizationKey is listed without a value |
| ChangeConfiguration | Accepted / Rejected / RebootRequired / NotSupported. AuthorizationKey (Security Whitepaper A01): 16 - 40 characters, then a reconnect with the new Basic Auth password; Rejected with profile 3 |
| Reset | Soft / Hard: ends transactions, disconnects, reconnects and boots again |
| TriggerMessage | BootNotification / Heartbeat / MeterValues / StatusNotification / FirmwareStatusNotification / DiagnosticsStatusNotification (the current step while an update / upload runs, else Idle) |
| UnlockConnector | Always answers Unlocked (other answers are not configurable yet); a running transaction on the connector ends with reason UnlockCommand |
| ChangeAvailability | Accepted / Rejected / Scheduled (Scheduled while a transaction is running) |
| DataTransfer | Default answer UnknownVendorId |
| SetChargingProfile | ChargePointMaxProfile (connector 0 only) / TxDefaultProfile / TxProfile (needs a running transaction) |
| ClearChargingProfile | Filters id / connectorId / chargingProfilePurpose / stackLevel |
| GetCompositeSchedule | Optional chargingRateUnit; same evaluator as the live power limit |
| SendLocalList | Full / Differential. listVersion must be > 0 (else CALLERROR PropertyConstraintViolation); a Differential update must raise it (VersionMismatch). More entries than SendLocalListMaxLength, duplicate tags, a Full entry without idTagInfo or more than LocalAuthListMaxLength tags → Failed (the list is unchanged); NotSupported while LocalAuthListEnabled is false |
| GetLocalListVersion | The stored version; 0 before the first list |
| ClearCache | Clears the Authorization Cache; Rejected while AuthorizationCacheEnabled is false |
| ReserveNow | Faulted / Unavailable / Occupied by the connector state, else Accepted; the same reservationId replaces a reservation; connector 0 keeps one connector free (Rejected while ReserveConnectorZeroSupported is false). A reserved connector reports Reserved and starts only for the reserved idTag or a tag with that parent; the reservationId goes with StartTransaction. It ends on expiry, cancel, or when the connector becomes Faulted / Unavailable |
| CancelReservation | Accepted for a known reservation, else Rejected |
| UpdateFirmware | Simulated, nothing is downloaded: waits for retrieveDate, retries / retryInterval on a download failure; connectors without a transaction are Unavailable until no transaction is left, then it installs and reboots (as a Hard Reset). Step durations and failure injection: maintenance per charger (download_s, install_s, upload_s, retry_interval_s, fail_download, fail_install, fail_upload). A new request replaces one that is not installing yet; one received while installing is ignored |
| GetDiagnostics | Answers fileName <id>-diagnostics-<time>.log and simulates the upload (nothing is uploaded); a new request replaces a running upload |
| ExtendedTriggerMessage | Security Whitepaper: BootNotification / Heartbeat / MeterValues / StatusNotification as TriggerMessage, plus SignChargePointCertificate; FirmwareStatusNotification (it means SignedFirmwareStatusNotification) and LogStatusNotification are NotImplemented; connectorId 0 is CALLERROR PropertyConstraintViolation (the whitepaper requires connectorId > 0) |
| CertificateSigned | Security Whitepaper; as 2.0.1: Accepted for a chain matching the outstanding CSR, then (profile 3) reconnect with it |
| InstallCertificate / DeleteCertificate / GetInstalledCertificateIds | Security Whitepaper; CentralSystemRootCertificate / ManufacturerRootCertificate, as 2.0.1 |
OCPP 2.0.1¶
Subprotocol ocpp2.0.1. connectors: N is a station with N EVSEs of one connector each; wherever the web UI or
the HTTP API says "connector" for a 2.0.1 charger, it means the EVSE id. The settings the station acts on are
Device Model variables (see Configuration), not 1.6 configuration keys. Where the
specification leaves a point open, the notes below give the simulator's interpretation.
Charging station to CSMS¶
| Message | Support | Notes |
|---|---|---|
| Authorize | Supported | Depends on auth_mode; a token presented at the charger is sent with type ISO14443. Status values the simulator does not model (NoCredit, NotAtThisTime, ...) are shown to the operator as Invalid |
| BootNotification | Supported | Accepted / Pending / Rejected. reason is PowerUp, RemoteReset after a CSMS Reset, Triggered after a TriggerMessage. Until the boot is accepted only BootNotification is sent, except what a TriggerMessage asks for while Pending (B02.FR.02). While Pending, RequestStart/StopTransaction are Rejected (B02.FR.05); while Rejected every CSMS request is answered CALLERROR SecurityError (B03) |
| ClearedChargingLimit | Supported | When the external limit is removed (chargingLimitSource EMS); only while the boot is accepted, see Smart Charging |
| DataTransfer | Supported | Sent manually from the UI or the HTTP API |
| FirmwareStatusNotification | Supported | Progress of UpdateFirmware with its requestId; on TriggerMessage the last status, Idle when it was Installed or none |
| Get15118EVCertificate | Not supported | ISO 15118 |
| GetCertificateStatus | Not supported | ISO 15118 |
| Heartbeat | Supported | Every OCPPCommCtrlr.HeartbeatInterval (also set by an accepted BootNotification) |
| LogStatusNotification | Supported | Progress of GetLog (Uploading → Uploaded / UploadFailure; AcceptedCanceled for an upload a new GetLog cancelled); on TriggerMessage Uploading while uploading, else Idle |
| MeterValues | Supported | Sent on TriggerMessage (context Trigger, measurands from AlignedDataCtrlr.Measurands); transaction readings travel in TransactionEvent |
| NotifyChargingLimit | Supported | When the external limit is set (chargingLimitSource EMS; with the schedule when SmartChargingCtrlr.NotifyChargingLimitWithSchedules is true); only while the boot is accepted, see Smart Charging |
| NotifyCustomerInformation | Not supported | |
| NotifyDisplayMessages | Not supported | |
| NotifyEVChargingNeeds | Not supported | ISO 15118 |
| NotifyEVChargingSchedule | Not supported | ISO 15118 |
| NotifyEvent | Not supported | A fault is reported only as the stoppedReason of the interrupted transaction |
| NotifyMonitoringReport | Not supported | |
| NotifyReport | Supported | Answers GetBaseReport in parts (DeviceDataCtrlr.ItemsPerMessage[GetReport] entries each, seqNo from 0, tbc on all but the last) |
| PublishFirmwareStatusNotification | Not supported | |
| ReportChargingProfiles | Supported | Answers GetChargingProfiles: one part per EVSE and chargingLimitSource, tbc on all but the last |
| ReservationStatusUpdate | Supported | Expired at expiryDateTime, Removed when the reserved EVSE (no evseId: the station) becomes Faulted / Unavailable |
| SecurityEventNotification | Supported | StartupOfTheDevice, ResetOrReboot, FirmwareUpdated, InvalidCsmsCertificate, InvalidTLSVersion, FailedToAuthenticateAtCsms, InvalidChargingStationCertificate, DiscardedRenewedClientCertificate, ReconfigurationOfSecurityParameters. Critical events are queued while offline and sent after the next accepted boot; non-critical ones only when they happen while connected |
| SignCertificate | Supported | After TriggerMessage SignChargingStationCertificate: a new EC P-256 key and a CSR (CN = serial, or the charger id without one; O = SecurityCtrlr.OrganizationName), certificateType ChargingStationCertificate. An unanswered CSR is not resent (CertSigningWaitMinimum is not modelled) |
| StatusNotification | Supported | One per EVSE (connector 1), none for EVSE 0. connectorStatus Available / Occupied / Reserved / Unavailable / Faulted; the finer state (charging, suspended) is the chargingState of TransactionEvent |
| TransactionEvent | Supported | Started → Updated → Ended. The station generates the transactionId (a UUID); seqNo counts from 0 per transaction; periodic Updated every SampledDataCtrlr.TxUpdatedInterval; offline: true for events raised while disconnected. Started carries SampledDataCtrlr.TxStartedMeasurands; Ended carries the union of SampledDataCtrlr and AlignedDataCtrlr TxEndedMeasurands at the start (Transaction.Begin) and end (Transaction.End), the sampled ones every SampledDataCtrlr.TxEndedInterval from the start (Sample.Periodic; 0 = start and end only) and the aligned ones at every AlignedDataCtrlr.TxEndedInterval clock boundary (Sample.Clock; 0 = none). As in 1.6, a measurand the meter does not report is refused: the *Measurands variables have the five reported measurands as valuesList, so SetVariables answers Rejected |
TransactionEvents and state-change StatusNotifications go through one ordered queue, as in 1.6. A failed
TransactionEvent is retried OCPPCommCtrlr.MessageAttempts[TransactionEvent] times,
MessageAttemptInterval[TransactionEvent] × failures apart; one whose answer was lost in a disconnect is sent
again after the next accepted boot (the CSMS can de-duplicate by transactionId + seqNo).
In the simulator's interpretation a transaction starts when the cable is plugged in and the id token is
authorized (triggerReason CablePluggedIn or Authorized, whichever comes last) and ends on the same token
presented again or an operator stop (StopAuthorized / Local), an unplugged cable (EVCommunicationLost), an
operator fault (AbnormalCondition; the fault code is the stoppedReason) or a token the CSMS refuses in a
TransactionEvent answer (Deauthorized, while TxCtrlr.StopTxOnInvalidId is true). With StopTxOnInvalidId false the transaction goes on, but the energy transfer stops at once (Updated ChargingStateChanged, SuspendedEVSE).
CSMS to charging station¶
| Message | Support | Notes |
|---|---|---|
| CancelReservation | Supported | Accepted for a known reservation (no ReservationStatusUpdate), else Rejected |
| CertificateSigned | Supported | Accepted for a chain whose certificate matches the outstanding CSR and is valid now (the CA hierarchy is not checked; the CSMS checks it in the next TLS handshake), else Rejected with InvalidChargingStationCertificate. With profile 3 the station reconnects with the new certificate; if that connection fails it falls back to the old one (DiscardedRenewedClientCertificate). V2GCertificate is Rejected |
| ChangeAvailability | Supported | No evse or EVSE 0 sets the station's own availability, kept apart from the EVSEs' (an EVSE Operative does not undo a station Inoperative). Going Inoperative while a transaction runs (on the EVSE, or on any EVSE for the station) is Scheduled until it ends; idle EVSEs follow a station Inoperative at once |
| ClearCache | Supported | Clears the Authorization Cache; Rejected while AuthCacheCtrlr.Enabled is false |
| ClearChargingProfile | Supported | chargingProfileId wins over the criteria, the criteria are ANDed; external constraints are never cleared by the CSMS |
| ClearDisplayMessage | Not supported | |
| ClearVariableMonitoring | Not supported | |
| CostUpdated | Not supported | |
| CustomerInformation | Not supported | |
| DataTransfer | Supported | Default answer UnknownVendorId |
| DeleteCertificate | Supported | Accepted / NotFound by the hash data (any of SHA256 / SHA384 / SHA512); the client certificate cannot be deleted (Failed) |
| GetBaseReport | Supported | ConfigurationInventory (every variable that is not ReadOnly), FullInventory, SummaryInventory; the NotifyReport parts follow the answer |
| GetChargingProfiles | Supported | Accepted when a profile matches, else NoProfiles; the ReportChargingProfiles parts follow the answer |
| GetCompositeSchedule | Supported | Same evaluator as the live power limit; periods are capped at the hardware maximum, which also stands for "no limit". Unknown EVSE or duration < 1 → Rejected; a chargingRateUnit not in SmartChargingCtrlr.RateUnit → Rejected (UnsupportedRateUnit) |
| GetDisplayMessages | Not supported | |
| GetInstalledCertificateIds | Supported | SHA256 hash data of the installed CA certificates; NotFound when none matches (V2GCertificateChain never does) |
| GetLocalListVersion | Supported | The stored version; 0 before the first list or while LocalAuthListCtrlr.Enabled is false |
| GetLog | Supported | Accepted with filename <id>_<logType>_<time>.log, or AcceptedCanceled when it cancels a running upload; the upload is simulated (maintenance settings) |
| GetMonitoringReport | Not supported | |
| GetReport | Not supported | Use GetBaseReport |
| GetTransactionStatus | Not supported | |
| GetVariables | Supported | Attribute types Actual / Target / MinSet / MaxSet; UnknownComponent / UnknownVariable / NotSupportedAttributeType; a WriteOnly variable is Rejected. More items than DeviceDataCtrlr.ItemsPerMessage[GetVariables] → CALLERROR OccurrenceConstraintViolation |
| InstallCertificate | Supported | One PEM certificate, valid now; Rejected for anything else or when 20 CA certificates are installed. Installed CSMS root certificates are trusted for the next TLS connection. Kept in memory only |
| PublishFirmware | Not supported | |
| RequestStartTransaction | Supported | remoteStartId and an optional chargingProfile (a TxProfile without transactionId, installed bound to the new transaction). Without evseId the first startable EVSE with a plugged cable is used. With AuthCtrlr.AuthorizeRemoteStart true the token is authorized like a presented one. A token of type Central or NoAuthorization is never authorized. A transaction started by it has triggerReason RemoteStart, also when the cable comes later. A token still waiting for the cable after TxCtrlr.EVConnectionTimeOut is dropped |
| RequestStopTransaction | Supported | Accepted for a running transaction of this station (it ends with RemoteStop), else Rejected |
| ReserveNow | Supported | Faulted / Unavailable / Occupied by the EVSE state, else Accepted; the same id replaces a reservation; without evseId one EVSE is kept free (Rejected while ReservationCtrlr.NonEvseSpecific is false); connectorType is not modelled; Rejected while ReservationCtrlr.Enabled is false. A reserved EVSE reports Reserved and starts only for the reserved idToken or a token of its groupIdToken; the reservationId goes with the Started event |
| Reset | Supported | Immediate / OnIdle (Scheduled while a transaction runs); the next BootNotification has reason RemoteReset. An EVSE reset is Rejected |
| SendLocalList | Supported | Full / Differential. versionNumber must be > 0 (else CALLERROR PropertyConstraintViolation); a Differential update must raise it (VersionMismatch). More entries than LocalAuthListCtrlr.ItemsPerMessage, duplicate tokens or a Full entry without idTokenInfo → Failed; Failed while LocalAuthListCtrlr.Enabled is false |
| SetChargingProfile | Supported | ChargingStationMaxProfile (EVSE 0 only), TxDefaultProfile, TxProfile; ChargingStationExternalConstraints is Rejected from the CSMS (UnsupportedPurpose). One chargingSchedule only. See Smart Charging |
| SetDisplayMessage | Not supported | |
| SetMonitoringBase | Not supported | |
| SetMonitoringLevel | Not supported | |
| SetNetworkProfile | Not supported | |
| SetVariableMonitoring | Not supported | |
| SetVariables | Supported | Values are checked (data type, limits, values list); a ReadOnly variable is Rejected; RebootRequired for variables marked so. Changes apply at once and are not written back to the YAML file |
| TriggerMessage | Supported | BootNotification (only while the boot is not accepted), Heartbeat, StatusNotification, MeterValues, TransactionEvent (readings from TxUpdatedMeasurands), LogStatusNotification / FirmwareStatusNotification (current status); other requested messages answer NotImplemented. All but BootNotification are Rejected before a BootNotification answer and served while Accepted or Pending. Unknown EVSE → Rejected |
| UnlockConnector | Supported | Unlocked; OngoingAuthorizedTransaction while the EVSE has a transaction (it is not stopped); UnknownConnector for an unknown EVSE or a connector other than 1 |
| UnpublishFirmware | Not supported | |
| UpdateFirmware | Supported | Simulated, nothing is downloaded or verified: DownloadScheduled (future retrieveDateTime) → Downloading → Downloaded → SignatureVerified (with signature) → InstallScheduled (future installDateTime) → EVSEs without a transaction Unavailable until none is left → Installing → InstallRebooting → reboot (BootNotification reason FirmwareUpdate) → Installed. retries / retryInterval on a download failure; AcceptedCanceled when it cancels an update that is not installing yet, Rejected while installing. Timings and failure injection: maintenance per charger |
Not supported yet¶
| Feature | Status |
|---|---|
| OCPP 2.1 | Planned for v0.3 (greyed out in the UI) |
| 1.6 Security Whitepaper SignedUpdateFirmware, GetLog, LogStatusNotification, SignedFirmwareStatusNotification | Not supported (CALLERROR NotImplemented) |
| ISO 15118 / Plug & Charge | Not supported (paid standard) |