HTTP API¶
The web UI uses the same HTTP API that your test scripts can call. Base URL: http://127.0.0.1:8082.
Errors: an unknown charger is 404; invalid input, or an operation the current state does not allow, is 400
(request validation errors are 400 as well). A DataTransfer the CSMS does not answer in time is 504, one it
answers with CALLERROR is 502.
Successful requests answer {"ok": true, ...} (GET routes return the data itself).
Common routes¶
| Method | Path | Meaning |
|---|---|---|
| GET | /api/version |
Version |
| GET | /api/state |
Full state snapshot: chargers, connectors, values |
| GET / PUT | /api/config |
Current configuration (PUT applies a new one; only changed chargers reconnect) |
| POST | /api/config/save |
Write the configuration back to the YAML file (see Configuration); 500 when the file cannot be written |
| POST | /api/simulation |
Run / pause and time scale: {"running": true, "time_scale": 10} (both optional; other fields are rejected) |
| GET / PUT | /api/csms-defaults |
The csms_defaults block (PUT replaces it and reloads) |
| GET / PATCH | /api/chargers/{id}/settings |
Connection / authorization settings of one charger (see below) |
| GET | /api/chargers/{id}/configuration |
Run-time configuration keys as GetConfiguration sees them; OCPP 2.0.1: the Device Model variables (see below) |
| POST | /api/devices |
Add a charger |
| GET / PUT | /api/devices/{id}/config |
One charger's configuration (PUT replaces the whole item) |
| POST | /api/devices/{id}/duplicate |
Copy a charger (the id is incremented) |
| DELETE | /api/devices/{id} |
Remove a charger |
Passwords are always returned as ********; sending the mask back keeps the stored password. Since a PUT
replaces the whole item, an omitted password means no password.
/api/chargers/{id}/settings covers csms_url, ocpp_version, password, ca_file, client_cert_file, client_key_file,
verify_tls,
id_tags and config_keys, plus the effective CSMS URL and OCPP version. PATCH changes only the fields
it contains; null unsets a field (id_tags / config_keys become empty; verify_tls must be true or
false). The password mask round-trips as above. Changes are applied with a configuration reload and are
written to the file only by POST /api/config/save.
For an OCPP 2.0.1 charger /api/chargers/{id}/configuration returns {"keys": [], "ocpp_version": "2.0.1",
"variables": [...]}: one entry per Device Model variable with component, component_instance, evse_id,
connector_id, variable, variable_instance, data_type, mutability, unit, min_limit, max_limit,
values_list, reboot_required and attributes (the Actual / Target / MinSet / MaxSet values it has;
null for a WriteOnly variable), incl. the values the CSMS changed with SetVariables. There is no route to change
a variable: the CSMS uses SetVariables, and the YAML file sets the start values (variables:).
Excel and templates¶
See Excel import / export and charger templates for the workbook layout and the template rules.
| Method | Path | Meaning |
|---|---|---|
| GET | /api/config/xlsx |
The chargers, config keys, variables and EV models as an Excel workbook (passwords as ********) |
| GET | /api/config/xlsx-template |
A blank workbook with the column headers |
| POST | /api/config/import |
Multipart field file: apply a workbook (all or nothing). {"ok": true, "warnings": [...]}, or 400 with errors: one message per problem, naming sheet, row and column |
| GET | /api/templates |
Charger templates: name, title, description, params, source (builtin / user) |
| POST | /api/templates/reload |
Read the user template directory again: {"dir", "loaded", "errors", "templates"} |
| POST | /api/templates/from-device/{id} |
{"name", "title"?, "description"?, "overwrite"?}: save a charger's template fields as a user template (409 when it exists and overwrite is not set) |
| POST | /api/chargers/bulk/create |
{"id": "CP-0001", "count": 10, "template"?, "params"?, "password"?, "fields"?}: add count chargers in one reload; the ID and a password ending in digits count up, fields are further charger fields for each (csms_url, ocpp_version, id_tags …). 409 when an ID exists already (nothing is added) |
Charger operations¶
| Method | Path | Body |
|---|---|---|
| GET | /api/chargers/{id} |
— the charger's snapshot plus fault_codes, the fault codes of its OCPP version |
| POST | /api/chargers/{id}/connect |
— (starts the connection loop) |
| POST | /api/chargers/{id}/disconnect |
— (stays disconnected until connect; transactions survive like a network loss) |
| POST | /api/chargers/{id}/plug |
{"connector": 1} |
| POST | /api/chargers/{id}/unplug |
{"connector": 1} |
| POST | /api/chargers/{id}/swipe |
{"connector": 1, "id_tag": "04A1B2C3"} — id_tag is required |
| POST | /api/chargers/{id}/start |
{"connector": 1, "id_tag": "04A1B2C3"} — plug in and swipe; id_tag defaults to the first configured tag (400 when there is none); 400 when the connector already has a transaction or is faulted |
| POST | /api/chargers/{id}/stop |
{"connector": 1} |
| POST | /api/chargers/{id}/fault |
{"connector": 1, "error_code": "OtherError"} — one of the charger's fault_codes (1.6: ChargePointErrorCode; 2.0.1: the fault values of ReasonEnumType), 400 otherwise; ends a running transaction (1.6: reason Other; 2.0.1: stoppedReason = the code) and reports Faulted |
| POST | /api/chargers/{id}/clear-fault |
{"connector": 1} — back to Available / Preparing |
| POST | /api/chargers/{id}/datatransfer |
{"vendor_id": "...", "message_id": "...", "data": "..."} (charger → CSMS) |
| GET / PUT | /api/chargers/{id}/impairments |
{"block": {"RemoteStartTransaction": "NotSupported"}, "latency_ms": 200, ...} — command blocking, latency, periodic drops, see below |
| POST | /api/chargers/{id}/drop |
{"mode"?: "abort" \| "close", "reconnect_after_s"?} — drop the connection now, see below |
| POST | /api/chargers/{id}/send |
{"action": "Heartbeat", "payload": {}, "validate": true} or {"raw": "[2,\"id-1\",\"Heartbeat\",{}]"} — frame injection, see below |
| POST | /api/chargers/bulk/connect |
{"ids": ["CP-0001", "CP-0002"]}, ["CP-0001"] or {"all": true} |
| POST | /api/chargers/bulk/disconnect |
same as above |
Bulk operations are not atomic: chargers are handled one after the other, and an error stops the request with the earlier ones already changed.
Command blocking and frame injection¶
Command blocking (impairments.block of a charger, see Configuration):
GET /api/chargers/{id}/impairments returns the block, PUT replaces it as a whole (400 for an action the
charger's OCPP version does not receive; GET /api/chargers/{id} lists those it does as csms_actions). The
change is applied to the running charger at once, without a reconnect, and is written to the file by
POST /api/config/save. A blocked CSMS → charger CALL is answered with CALLERROR NotImplemented or
NotSupported (the same wire names in OCPP-J 1.6 and 2.0.1), or, with NoReply, not at all, so the CSMS runs
into its own timeout. The frame log marks the received CALL with blocked: <code> / blocked: no reply, and the
charger snapshot has impaired: true (the UI shows ! on the badge). In the UI: Impairments in the
charger detail panel.
Network impairments¶
The same impairments block also holds the latency (latency_ms, jitter_ms, direction, seed) and the
periodic drops (drop_every_s, drop_jitter_s, drop_mode, down_s), see
Configuration. PUT takes the whole block (fields left out get their defaults;
400 for out-of-range values, e.g. jitter_ms > latency_ms) and applies it to the open connection without a
reconnect: the next frame already gets the new delay.
POST /api/chargers/{id}/drop drops the connection now and returns {"ok": true, "mode", "reconnect_after_s"}.
mode defaults to drop_mode, reconnect_after_s (0 – 86400) to down_s; 409 while the charger is not
connected. The charger reconnects after that pause instead of its back-off. A simulated drop is not a
failed connection: it never counts against reconnect.max_retries / boot_max_retries, even before an accepted
boot. Transactions and queued messages are kept. The snapshot shows last_error.kind simulated_drop until
the next accepted boot and counts the drops in drops; impaired is true while any impairment is on. In the
UI: Impairments in the charger detail panel (also Drop now).
Frame injection (POST /api/chargers/{id}/send) is an expert entry for testing how a CSMS handles messages
the simulator would not send on its own:
{"action", "payload", "validate": true, "timeout"}sends one CALL and returns{"ok": true, "result": {...}}, or{"ok": false, "error": {"code", "description", "details"}}for a CALLERROR;504on timeout (timeoutin seconds, default the call timeout). Withvalidate: truethe action must be a charger → CSMS action of the charger's version and the payload must match its request schema (400otherwise); an answer that does not match the response schema adds awarning.validate: falsesends any action and any JSON payload.{"raw": "<text>"}writes the text to the WebSocket verbatim and waits for nothing; an answer to it shows up in the frame log as an unsolicited response.- The station state never changes: an injected StartTransaction creates no transaction, an injected
StatusNotification changes no connector. Injected frames are marked
injected/injected (raw)in the frame log.409while the charger is not connected. - One CALL is outstanding per connection (OCPP-J), so the charger's own CALLs (Heartbeat, MeterValues, ...)
queue behind an injected CALL until it is answered or times out;
timeoutis therefore at most 60 s. rawand the serializedpayloadare limited to 1,000,000 characters (400/413). A raw frame whose uniqueId is that of a pending charger CALL is refused with409(its answer would resolve that call).
Smart Charging¶
| Method | Path | Meaning |
|---|---|---|
| GET | /api/chargers/{id}/profiles?connector= |
Installed charging profiles |
| GET | /api/chargers/{id}/composite?connector=&duration=&unit= |
The GetCompositeSchedule answer computed locally (connector 0 = whole charge point; evse is accepted as an alias) |
| POST | /api/chargers/{id}/external-limit |
Body {"connector": 0, "limit_w": 7000} (limit_w null = remove). An external (energy management) limit: OCPP 2.0.1 installs a ChargingStationExternalConstraints profile and sends NotifyChargingLimit / ClearedChargingLimit; OCPP 1.6 answers 400 (not supported) |
For an OCPP 2.0.1 charger connector is the EVSE id (0 = the whole station).
Frame log¶
| Method | Path | Meaning |
|---|---|---|
| GET | /api/frames?since=&until=&charger=&action=&dir=&limit= |
OCPP frames with since < seq <= until, filtered by charger, action and direction |
| GET | /api/frames.jsonl?... |
The same as a streamed JSON Lines download (without limit: every matching frame in the buffer) |
/api/frames returns {"frames": [...], "last_seq": n, "truncated": bool}: at most the newest limit
matching frames (default 500, maximum 5000), oldest first. truncated: true means older matching frames were
left out; last_seq is the newest sequence number of the whole log (filters ignored).
The frame log contains OCPP frames only, never HTTP headers or passwords.
Mini CSMS¶
Routes of the built-in Mini CSMS. Station ids are the ids the stations connected with.
| Method | Path | Meaning |
|---|---|---|
| GET | /api/csms |
Status (enabled, running, error, url, versions, ...), the stations (chargers) and refused connections (rejections) |
| GET | /api/csms/chargers/{id} |
One station: boot info, last status per connector / EVSE, transactions, recent meter values, counts and last payload per action, warnings, sent CALLs, plan state |
| GET | /api/csms/transactions |
Transactions of every station |
| GET | /api/csms/actions?version= |
CSMS → CP actions that can be sent for 1.6 / 2.0.1 |
| POST | /api/csms/chargers/{id}/call |
Body {"action", "payload", "timeout"?}. Checked against the schema (400 naming the field), then sent. Answer {"ok": true, "result"} (plus warning if the answer does not match its schema) or {"ok": false, "error": {"code", "description", "details"}} for a CALLERROR |
| GET | /api/csms/frames?since=&charger=&limit= |
The Mini CSMS's own frame log (direction seen from the CSMS) |
Errors: 404 unknown station, 400 schema mismatch, 409 station not connected, 504 no answer in time, 409 while the
Mini CSMS is not running (except GET /api/csms).
WebSocket /ws¶
Clients that want live updates connect to ws://127.0.0.1:8082/ws:
- The first message is
{"type": "snapshot", "data": ...}with the same content asGET /api/state. - Then the engine pushes
charger_state,valuesandframemessages, each with apush_seqcounting 1, 2, 3 ... per connection. - Engine events arrive as
{"type": "log", "event": {...}}, numbered by their ownevent.seq(nopush_seq). - After a configuration reload a new
{"type": "snapshot"}is sent.
A gap in push_seq means messages were dropped for a slow client. If a state push or a reload notice was among
them, the next state push is a full one ("full": true), so the state heals by itself (or refetch
/api/state). Lost frames can be fetched with GET /api/frames?since=<last frame seq seen>. A full
charger_state lists every charger: replace your charger list with it (a missing charger was removed by a
reload); a full values replaces all values likewise. Do not rely on the order of the two full pushes.