Life Safety Point 与 Life Safety Zone¶
- {type: lsp, name: Smoke-101, description: Smoke detector} # life-safety-point (object type 21)
- type: lsp
name: Heat-101
value: quiet # initial state (BACnetLifeSafetyState: quiet, pre-alarm, alarm, fault, ...)
mode: "on" # BACnetLifeSafetyMode (default on; quote on / off in YAML)
accepted_modes: ["on", "off", test] # default [off, on, test]
operation_expected: none # BACnetLifeSafetyOperation, read-only (default none)
silenced: unsilenced # initial BACnetSilencedState
behavior: {type: random_alarm, probability: 0.001, state: alarm} # optional, per sim second
- {type: lsz, name: Zone-101, zone_members: [Smoke-101, Heat-101]} # life-safety-zone (object type 22)
完整的状态机只在 ASHRAE 135 中定义,模拟器使用简化模型:
- Tracking_Value 是探测器的实时状态。可在 UI(行的探测状态菜单,
POST /api/devices/{id}/life-safety/{type:instance}/state)或用可选的random_alarmbehavior(随机变为state,下一个 tick 回到quiet)设置。对 BACnet 客户端只读。 - Present_Value 在 Tracking_Value 非
quiet时跟随它,回到quiet后保持锁存直到 reset。 对 present-value 的 BACnet 写入仅在 out-of-service 时接受。 - Zone 的 Tracking_Value 取 Zone_Members 顺序中第一个非
quiet成员的 present value(全部quiet则为quiet)。这是简化:不应用状态之间的严重程度顺序。 - LifeSafetyOperation:
silence/silence-audible/silence-visual置位、unsilence*清除 Silenced 的 audible / visible 部分;reset/reset-alarm/reset-fault(此处相同)把 Tracking_Value 复制到 Present_Value 并解除消音;none不做任何事。对 Zone 的操作也作用于其成员;不带 object identifier 时作用于 设备的所有 Life Safety 对象。厂商自定义操作返回services/optional-functionality-not-supported,其它对象 类型返回object/unsupported-object-type。所有操作都写入事件日志。 - mode 可写,但必须属于 accepted-modes(否则
property/value-out-of-range);zone-members 可写 (WriteProperty、AddListElement / RemoveListElement),并以成员名写回配置(指向其它设备的引用被忽略)。 - ReinitializeDevice 恢复配置的状态。EDE 导出包含它们(object type 21 / 22,值为状态编号),EDE 导入保留 类型、名称和状态。
不支持:change-of-life-safety 事件报告(不评估 alarm-values、life-safety-alarm-values、fault-values 及事件属性)、 状态的严重程度顺序与依赖模式的状态转换、maintenance-required / direct-reading / setting 的行为、用 CreateObject / DeleteObject 创建 / 删除 Life Safety 对象。